CANmeleonKH-UCANFDG2-Mini Series (4 / 6-CH Modules)
4 / 6-channel (G2X4-Mini / G2X6-Mini) compact USB CAN FD bare-board modules with GH1.25 headers and 3000 V isolation
Engineered for humanoid, quadruped, and OpenArm 1–2 kHz torque control loops with 4/6-CH compact bare-board modules, rugged terminal adapters, and verified ~42.2 μs mean latency.



Legacy USB-UART bridges introduce millisecond batching jitter that destabilizes high-rate impedance/torque loops.
Separating left/right arms, legs, and dexterous hands requires 4–8 independent CAN FD channels inside cramped, weight-sensitive robot torsos.
Back-EMF transients demand 3000 V isolation, while dangling stubs, misplaced terminators, and sample-point mismatches cause intermittent frame drops.
Click any product card to view series highlights or open full electrical specifications in Kunhong Docs.
CANmeleon4 / 6-channel (G2X4-Mini / G2X6-Mini) compact USB CAN FD bare-board modules with GH1.25 headers and 3000 V isolation
CANmeleonIndustrial 2-channel flanged USB CAN FD adapter with pluggable terminal block, DIP termination and 3000 V isolation
CANmeleonInternal 2 / 4-channel 3000 V isolated M.2 3052 B-Key CAN FD card for compact IPCs and edge controllers
CANmeleonUltra-compact 43 × 19 × 5 mm board-to-board USB CAN FD core modules (B2B-X2 / X4) for custom carrier boards
Inquiry2 / 4-channel USB-CAN FD controller ICs with integrated high-speed USB PHY in QFN48 for custom PCB designs
* Marked performance metrics depend on specific hardware editions, host OS configuration, and physical bus topology; consult individual datasheets in Kunhong Docs.
All second-generation Kunhong interfaces share one Linux SocketCAN / KCAN software stack — prototype with X2I or G2-Mini and scale to B2B core modules or KHCM104 ICs without rewriting upper-layer motor code.

4 / 6-channel (G2X4-Mini / G2X6-Mini) compact USB CAN FD bare-board modules with GH1.25 headers and 3000 V isolation
Specifications(Kunhong Docs)↗
Ultra-compact 43 × 19 × 5 mm board-to-board USB CAN FD core modules (B2B-X2 / X4) for custom carrier boards
Specifications(Kunhong Docs)↗
2 / 4-channel USB-CAN FD controller ICs with integrated high-speed USB PHY in QFN48 for custom PCB designs
Specifications(Kunhong Docs)↗One-way latency distributions, P99.9 jitter, and 1–2 kHz loop math.
Oscilloscope before/after analysis of stub reflections, termination, and sample points.
Bind deterministic interface names per limb bus across reboots on x86/ARM64 Linux.
Answers to frequent hardware selection and deployment questions.
Engineers typically dedicate one independent bus per limb (left arm, right arm, left leg, right leg, torso/hands) keeping 4–8 actuators per bus to meet 1–2 kHz cycle budgets. A single G2X4-Mini (4-CH) or G2X6-Mini (6-CH) covers the torso cleanly.
Using the udev channel-binding rules documented in our Linux SDK guide locks each physical port and serial number to a fixed interface name across reboots.