INDUSTRY & APPLICATION SOLUTIONS

System Topologies & Hardware Selection by Application

Inspect real connection diagrams and representative hardware across vehicle R&D benches, mobile ECU diagnostics, 1–2 kHz embodied robotics, and industrial IPCs.

HOST SYSTEMS
Windows x64 PC
Ubuntu PREEMPT_RT
Jetson / RK3588
Fanless IPC
KUNHONG ISOLATED INTERFACES
PRO-X2USB-CANFD
G2X6-MiniG2-Mini
NEPTUNE-26100/1000M T1
KHCM104KHCM104 IC
FOUR CORE APPLICATION DOMAINS

Click an application domain to view its wiring topology & matched series

AUTO · R&DCAN FD + 100/1000BASE-T1
HOSTTest PC / HIL
PRO-X2CAPT1GA
TARGETECUs & T1 Links
12 Mbps*Max CAN FD data rate (PRO / LITE)≈ 1 μs*Hardware timestamp resolution3000 VPRO series bus isolation

Automotive Network R&D

Multi-bus CAN FD synchronized acquisition, 100/1000BASE-T1 conversion & zero-delay packet capture, field road tests, and 8/16-CH benches.

PRO / MAX AdaptersNEPTUNE / CAPT1GA T1 Ethernet8 / 16-CH EVKs
View connection topology & matched series
AUTO · SERVICE & EOL120 Ω 按键 + DoIP 转换
HOSTService Laptop
LITE-X2UNEPTUNE-26
TARGETOBD / Bare ECU
1500–3000 VGalvanic bus isolation against transients120 ΩOn-device switchable 120 Ω terminationCANmeleonSwitchable firmware via device manager

Aftermarket & ECU Flashing

Tailored for mobile EV/commercial-vehicle diagnostics, ECU flashing, DoIP T1 Ethernet bridging, EOL test bays, and diagnostic tablet OEM hardware integration.

LITE / PRO Isolated AdaptersNEPTUNE DoIP ConvertersDiagnostic Tablet OEM
View connection topology & matched series
ROBOT · 1–2 KHZ1–2 kHz · 42.2 μs* 实时
HOSTJetson / RK3588
G2X6-MiniX2I
TARGETLimb Actuator Chains
42.2 μs*Verified mean one-way latency65.0 μs*Verified P99 latency (2.7M frames)4 / 6 CHIndependent GH1.25 channels per module

Embodied Robotics CAN FD

Engineered for humanoid, quadruped, and OpenArm 1–2 kHz torque control loops with 4/6-CH compact bare-board modules, rugged terminal adapters, and verified ~42.2 μs mean latency.

G2X4 / G2X6-Mini ModulesX2I Flanged TerminalB2B Core & KHCM104 IC
View connection topology & matched series
IND · IPC & AMR3000 V 隔离 · CANopen
HOSTFanless IPC
MP-X4X2I
TARGETServos / AGV
3000 VGalvanic isolation on industrial models−40~85 °CIndustrial operating temperatureM.2 / mPCIeStandard IPC internal slot form factors

Industrial Automation & IPC

3000 V isolated M.2 / MiniPCIe internal IPC cards, cabinet & AGV screw-terminal adapters, CANopen servo commissioning, and 24/7 line monitoring.

M.2 / MiniPCIe IPC CardsX2I Cabinet TerminalKH-CanOpenTool
View connection topology & matched series
CROSS-DOMAIN PRODUCT OVERLAP

Product series × industry scenario selection matrix

See how active product series overlap across industries depending on connector style, isolation, and mounting.

Primary recommended seriesScenario-specific option
Active product seriesAutomotive Network R&D ↗ Aftermarket & ECU Flashing ↗ Embodied Robotics CAN FD ↗ Industrial Automation & IPC ↗
Portable Adapter (LITE-X2U)○ Portable road tests● Mobile field diagnostics○ Single-motor bench setup○ Field maintenance
Bench Adapters (PRO · MAX-X4)● Multi-bus ECU benches● EV & 24 V service bays——
Flanged Terminal Adapter (X2I)—○ EOL test cabinets● Manipulator rigs & bases● Cabinets & AGV chassis
Compact Bare-Board (G2-Mini 4/6-CH)—○ Tester internal build● Humanoid/quadruped torso○ Compact machine OEM
Internal Cards (M.2 & MiniPCIe)○ Rack test IPCs—○ Compute-box internal slot● Fanless IPC expansion
B2B Core, 8/16-CH EVKs & KHCM100 IC● 8 / 16-CH burn-in rigs● Diagnostic tablet OEM● Custom mainboard & IC OEM○ Custom PLC / HMI OEM
Automotive Ethernet (T1 / T1S)● Conversion, switch & zero-delay TAP● Smart-vehicle DoIP flashing○ Domain Ethernet links—

* Rate and latency figures depend on hardware configuration, host OS, and bus topology; refer to the Kunhong Documentation Center for complete specifications.

PROTOTYPE TO VOLUME OEM

Three-tier hardware progression on one unified software stack

Prototype with enclosed adapters or bare-board modules, then scale to B2B core modules or QFN48 controller ICs without rewriting SocketCAN / KCAN code.

Compact Bare-Board & Slot Cards
STAGE 01Prototype & Small Batch

Compact Bare-Board & Slot Cards

G2X4/X6-Mini · X2I · M.2 / MiniPCIe

Ready-made 3000 V isolation and locking GH1.25 / screw terminals for robot torsos, IPC slots, and cabinets.

View modules & cards →
43 × 19 mm B2B Core Modules
STAGE 02Mid-Volume Custom Carrier

43 × 19 mm B2B Core Modules

KH-UCANFD-B2B-X2 / X4

Plug a pre-validated 2- or 4-channel CAN FD core module onto your custom diagnostic tablet, HIL carrier board, or robot PDB.

View B2B core series →
QFN48 USB-CAN FD Controller ICs
STAGE 03High-Volume Custom PCB

QFN48 USB-CAN FD Controller ICs

KHCM102 (2-CH) · KHCM104 (4-CH)

Integrate 2 or 4 CAN FD channels with built-in High-Speed USB 2.0 PHY directly onto your motherboard BOM.

Explore KHCM100 ICs →
ENGINEERING CONSULTATION

Have cross-domain or custom OEM requirements?

Tell us your bus count, target cycle rate, host platform (Windows, Ubuntu, Jetson, RK3588), and mechanical constraints.